RF DigiMax 210 Rear View
Cut Link 1 for 16°C minimum set point
Cut Link 2 to display cooling symbol
instead of heating symbol
Batteries
Link 2
Link 1
3 2 1
Terminal block
a) Commissioning
The RF DigiMax 210 is required to be matched with the RF-
Max receiver. This is to ensure only the correct thermostat is
controlling your ambient temperature. The thermostat sends
a signal which is a unique code (1 of 65000), which only the
matched RF-Max receiver is capable of understanding. From
this moment, the RF-Max will only answer to signals sent by
this thermostat
RF link between the Thermostat RF DigiMax 210
and the RF-Max