6.8.2. REFERENCE
ADDRESS FOR HOME
AUTOMATION
28 MARMITEK
To control various Home Automation modules,
the reference address has to be set on the
SC2800 base station. The address A1 is the
factory default. The A in this address is the House
Code (HC). Under normal circumstances, the
House Code of the base station, remote controls
and Home Automation modules must be on the
same letter code. The 1 in the reference address
is called Unit Code (UC).
The SC2800 base station normally transmits
signals to various addresses to activate e.g. extra
sirens. The functions are preprogrammed into the
base station. An addressing method "with respect
to the reference address of the base station" is
used to achieve these functions. When multiple
Marmitek X-10 Home Automation systems are
placed in the house, it can be necessary to
change the Unit Code of the base station.
4. LIFESTYLE
FUNCTION
Modules will be
switched on and off
to simulate your presence (refer to 6.9).
MARMITEK X-10
MODULE SET TO A3
A4
5. EXTERNAL
SIREN -
UNIVERSAL
This function will
activate an AD10 (Art.No. 08933, separately
available) during an alarm and will be
automatically switched off after 4 minutes.
You now can place multiple sirens without
installing extra cables.
MARMITEK X-10
MODULE SET TO B5
7. OFF WHEN AWAY
Module will be
switched off as soon
as the system is
disarmed. Will often
be used in combination with scenes/macro’s
(wake up, leave, come home, sleep, etc.) of the
Marmitek X-10 CM11 Computer Interface.
For more information ask your dealer or look at
our website: www.mamritek.com
MARMITEK X-10
MODULE SET TO B6
6. EXTERNAL
INDOOR SIREN
PH7208
The Marmitek Siren
works without extra wiring. The commands to
switch the siren on and off are sent through
the existing house wiring (Marmitek X-10
command "all lights on" and "all lights off").
These commands are being placed on the
existing house wiring by the SC2800 base
station. Note: the Siren has to be connected
on the same phase as the alarm console. If
this is not possible you need to use Phase
Coupler/Filter (FD10). To prevent false alarm
the systems waits 20 seconds before
triggering the Siren after activating the Alarm.
The Siren makes a piercing two-tone signal for
4 minutes when activated. After this the Siren
will be automatically switched off (or sooner
when the alarm is switched off). Note: When
you use a Marmitek Alarm System, the Sirens
always work during an alarm, regardless of the
function silent alarm is being switched on.
The PH7208 is designed for indoor use. You
can connect the PH7208 to a standard wall
outlet.
PH7208 SET TO A1